A novel technique for measurement of pericardial pressure
G deVries1, D R Hamilton, H E Ter Keurs
1Department of Medicine and Department of Physiology and Biophysics, University of Calgary, Calgary, Alberta, Canada T2N 4N1.
Abstract:
To determine whether pericardial liquid pressure accurately measures pericardial constraint, we developed a technique in which a catheter was positioned perpendicular to the epicardial surface. This device, which occupies little or no pericardial space, couples the thin film of liquid to a transducer. In six open-chest dogs, we also measured left ventricular (LV) end-diastolic pressure (LVEDP) and anteroposterior and septum-to-free wall diameters. LVEDP was raised incrementally to approximately 25 mmHg by saline infusion. With the use of the product of the two diameters as an index of area (A(LV)), LVEDP-A(LV) relationships were obtained with the pericardium closed and again after the pericardium had been widely opened to obtain the isovolumic difference in LVEDP (DeltaLVEDP). In all dogs, the technique yielded values of pericardial pressure equal to DeltaLVEDP as well as equal to that measured using a previously placed balloon transducer in the same location and at the same A(LV). We conclude that, when the pressure of the pericardial liquid is appropriately measured, it (in addition to the balloon-measured contact stress) defines the diastolic constraining effect of the pericardium. Furthermore, we suggest that earlier measurements of pericardial "liquid pressure" were low, due to an artifact of measurement.
More Related Videos
10:05Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine
Published on: July 7, 2016
09:37Permanent Ligation of the Left Anterior Descending Coronary Artery in Mice: A Model of Post-myocardial Infarction Remodelling and Heart Failure
Published on: December 2, 2014
Related Concept Videos
Pericarditis II: Clinical Features and Diagnostic Tests
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)