Related Experiment Video
Updated: Oct 7, 2026

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Breath-hold 3D MR coronary angiography with a new intravascular contrast agent (feruglose)--first clinical
J J Sandstede1, T Pabst, C Wacker
1Department of Radiology, University of Wuerzburg, Josef-Schneider-Strasse 2, D-97080 Wuerzburg, Germany. joern.sandstede@mail.uni-wuerzburg.de
Abstract:
Demonstration of the initial results of breath-hold 3D MR coronary angiography with patients using a new intravascular contrast agent (feruglose). Contrast-enhanced 3D MR-coronary angiography was performed in 5 patients with coronary artery disease after administration of feruglose in three different doses (0.5 (n = 3), 2, 5 mg Fe/kg body weight for each patient). MR coronary angiography was performed with an ECG-triggered 3D-FLASH-sequence during breath-hold at 1.5 T (TR 6.8 ms, TE 2.5 ms, flip-angle 30 degrees ). To reduce data acquisition time, only the two anterior elements of the phased-array body coil were activated. The data acquisition window within the cardiac cycle ranged between 217-326 ms depending on the matrix. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) of the coronary arteries were analyzed, and the results for the detection of coronary artery stenoses were compared with those obtained by conventional coronary angiography. SNR and CNR revealed an improved image quality at a dose of 2 mg Fe/kg compared with the lower dose, but no further improvement was obtained by rising the dose to 5 mg Fe/kg. Except for the left circumflex artery of one patient, at minimum the proximal parts of all four main coronary arteries could be imaged for all patients. Within the visible parts of the coronary arteries, six of eight significant coronary stenoses were identified correctly. Imaging of the proximal parts of the coronary arteries including detection of stenoses is possible during breath-hold using an intravascular contrast agent.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
10:16Retrograde Perfusion and Filling of Mouse Coronary Vasculature as Preparation for Micro Computed Tomography Imaging
Published on: February 10, 2012
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...