Evaluation of a surgical gamma probe for detection of 18F-FDG
S Yasuda1, H Makuuchi, H Fujii
1Department of Surgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan. yasuda@is.icc.u-tokai.ac.jp
Abstract:
Because fluorine-18 fluorodeoxyglucose (18F-FDG) is an excellent tumor-localizing radio-pharmaceutical, a hand-held radiation detection probe capable of localizing an area with high 18F-FDG uptake would make radioguided surgery possible. In this laboratory study, we investigated the capability of a widely used intraoperative gamma probe with a cadmium zinc telluride (CdZnTe) detector for detection of 18F-FDG. For sensitivity tests, an 0.1- ml 18F-FDG preparation was made to act as a point source with radioactivities of 1.0, 2.0, and 3.0micro Ci (37 kBq, 74 kBq, 111 kBq). Relative transmission across the side wall of the probe and sensitivity at each source-to-probe distance were measured. For simulation studies, 2 l of 18F-FDG solution (0.02micro Ci, 0.74 kBq/ml) served as normal background. One ml of 18F-FDG was prepared to simulate tumors with radioactivities of 0.05, 0.1, 0.2, and 0.4micro Ci (1.85 kBq, 3.7 kBq, 17.4 kBq, and 14.8 kBq). The ratios of the radioactive concentration of tumor to that of the background were 2.5, 5, 10, and 20:1, respectively. The tested gamma probe was shown to be sensitive to 18F. The high-energy annihilation radiation was detected from the side wall of the probe despite application of a supplementary collimator. The count rate decreased markedly as the source-to-probe distance increased, owing to the effects of the inverse-square law. In the simulation studies, the probe detected a considerable amount of background activity. However, the measured count rate increased with the increasing source-to-background ratio. In our setting, the probe was capable of distinguishing the 18F-FDG source from the background when the source-to-background ratio was no less than 5:1. To make a surgical application feasible, however, collimation or shielding against high background radiation is necessary.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)