Shape and movement of the interatrial septum predicts change in pulmonary capillary wedge pressure
C F Royse1, A G Royse, P F Soeding
1Department of Anaesthesia and Pain Management, The Royal Melbourne Hospital, P.O.Box 1022, Research, Victoria 3095, Australia.
Abstract:
We aimed to assess whether movement of the interatrial septum predicts change in pulmonary capillary wedge pressure (PCWP). In 71 patients undergoing cardiac surgery, the interatrial septum was categorised by its shape and movement using transesophageal echocardiography. Fixed curvature (FC) was identified by bowing of the interatrial septum from left to right throughout the cardiac cycle, mid-systolic reversal (MSR) by minimal septal movement and transient reversal (right to left) during mid-systole, and mid-systolic buckling (MSB) by marked movement and buckling of the septum during mid-systole. These were compared with PCWP. Sensitivity and interobserver reliability was studied with continuous PCWP and TEE measurement during a period of acute volume alteration in 10 additional patients. Interatrial septal movement predicted PCWP, with mean PCWP (95% confidence intervals) for FC, 18.1 mmHg (16.7 to 19.6), MSR 13.2 mmHg (12.5 to 13.8) and MSB, 9.9 mmHg (9.0 to 10.7) mmHg. The mean PCWP at which a change in pattern occurred was 8.9 mmHg (8.3 to 9.6) for MSR to MSB, and 10.9 mmHg (10.1 to 11.8) for MSR to FC (p<0.001). There was no significant difference in mean values for all three observers. Movement of the interatrial septum predicts change in PCWP.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Chambers of the Heart
Deoxygenated blood from the body is received in the right...
Mitral Stenosis I: Introduction
Pulmonary Edema II: Pathophysiology
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...