Related Experiment Video
Updated: Oct 7, 2026

Monitoring Protein Adsorption with Solid-state Nanopores
Published on: December 2, 2011
Effect of adsorbent porosity on performance of expanded bed chromatography of proteins
S Gondkar1, K Manudhane, N Amritkar
1Chemical Engineering Division, Department of Chemical Technology, University of Mumbai, Matunga, Mumbai, India 400 019.
Abstract:
Expanded bed or fluidized bed adsorption has emerged as an important unit operation in downstream processing of proteins. A number of specifically designed commercial adsorbents are available today for expanded bed purification of proteins. Protein purification essentially requires adsorbent matrices that have large pore size. Very large pore size or macroporous adsorbents can provide high efficiency in packed beds even at high flow rates on account of reduced pore diffusion resistance resulting from finite intraparticle flow in the macropores. This is reflected in leveling off of HETP (height equivalent to theoretical plate) versus flow curve after a threshold velocity. Expanded bed operation, on the other hand, can also show plateauing of the HETP curve, but not necessarily on account of macroporosity of adsorbent. It is shown in this article how any adsorbent intended for protein adsorption in expanded bed mode can give plateauing HETP curve, regardless of pore size. As a result, RTD measurements on an expanded bed can give equal, and at times better, performance than a corresponding packed bed. Large pore size, on the other hand, can result in lesser retention of biomass and easy flushing of the adsorbent to obtain an entirely particulate-free adsorbent prior to the product elution step. Adsorbent with larger pores is also shown to provide faster and more efficient elution both in packed and expanded bed modes.
Related Concept Videos
Analyte Adsorption and Distribution
Principles Of Column Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...

