Related Experiment Video
Updated: Aug 13, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Patient and occupational dosimetry in double contrast barium enema examinations
G J Kemerink1, A C Borstlap, M J Frantzen
1Department of Radiology, University Hospital Maastricht, P Debijelaan 25, 6229 HX Maastricht, The Netherlands.
Abstract:
A new and relatively simple method is presented to distribute total dose-area product (DAP) over a number of projections that model exposure during double contrast barium enema (DCBE) examinations. In addition, hitherto unavailable entrance and effective doses to the physician performing the DCBE examination have been determined. DAP, fluoroscopy time, number of images as well as some patient data were collected for 150 DCBE examinations. For a subset of 50 examinations, the distribution of DAP over 12 hypothetical but representative projections was estimated by measuring the entrance dose in the centre of each of these projections during the complete procedure. Effective dose to the patient was obtained using DAP to effective dose conversion coefficients calculated for each of the 12 projections. Exposure of the worker was quantified by measuring the entrance dose at the forehead, neck, arms, right hand and legs. The sex-averaged effective dose to the patient per examination was 6.4+/-2.1 mSv (mean+/-SD; n=50) and the corresponding DAP was 44+/-22 Gy cm(2). The effective dose to the worker per examination was 0.52 microGy (n=50), whereas the highest entrance dose of 30+/-25 microGy was found for the right arm. The proposed method for deriving the distribution of total DAP over a set of representative projections is much less time consuming than visual observation of patient exposure, whilst accuracy seems acceptable. Entrance and effective doses per examination for workers in DCBE examinations are very low. For a normal workload, doses remain far below the legally established dose limits.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Imaging Studies III: Computed Tomography