Related Experiment Video
Updated: Aug 7, 2026

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Poor man's LMA: achieving adequate ventilation with a poor mask seal
1Department of Anesthesiology, University of Alabama at Birmingham, 35249-6810, USA. kathryn.campbell@ccc.uab.edu
Purpose:
This report describes a technique of ventilation prior to laryngoscopy and intubation that proved to be simple, inexpensive and effective for a patient whose airway evaluation suggested difficult mask ventilation. The technique is called Poor Man's LMA.
Clinical Features:
A 60-yr-old male, measuring 170 cm, weighing 117 kg, edentulous and with a full beard, was to undergo uvulopalatopharyngoplasty. After induction of general anesthesia with a hypnotic, analgesic and non-depolarizing muscle relaxant, it was soon determined that mask bag ventilation was difficult due to an inadequate seal between the mask and the patient's full beard. To improve ventilation, an endotracheal tube was placed into the oropharynx, the lips and nose compressed by a colleague in order to prevent gas egress, and effective manual ventilation established by connecting the circle system to the endotracheal tube. Subsequent direct laryngoscopy and intubation were accomplished without incident.
Conclusion:
The patient's clinical features made conventional mask bag ventilation difficult and inadequate. The Poor Man's LMA technique improved oxygenation and ventilation in preparation for intubation. Further investigations on the usefulness of this technique are warranted.
More Related Videos
04:56Laryngeal Mask Airway (LMA) Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway (SGA)
Published on: July 14, 2023
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Cardiopulmonary Resuscitation II: ACLS Airway Management