On the clinical value of calibrated displacement apexcardiography
Abstract:
A new type of displacement transducer for recording the calibrated left apexcardiogram (QLAC) has been evaluated in 69 normal subjects and 99 cardiac patients. Total displacement of QLAC (TD), its peak first derviative (peak dD/dt (t-peak dD/dt). A strong corretation exists between peak dD/dt and TD in normal subjects (r=0.95) and the deviation from the normal relationship allows a separation between normal and abnormal ventricular function. In normal subjects (dD/dt/Dt) max averaged 34.2 plus or minus 5.7 sec-1; it was signigicantly lower in patients with congestive cardiomyopathy (26.5 plus or minus 6.3 sec-1 p greater than 0.005). This index correlates with left ventricular end-diastolic pressure (LVEDP) (R = - 0.69) and with ejection fraction (R - 0.66) and behaves as expected during positive and NEGATIVE INOTROPIC interventions. The index (dD/dt/Dt) max is superior to TD and peak dD/dt, being less variable independent of thorax circumference and better correlated with hemodynamic parameters. The index t-peak dD/dt was 53.9 plus or minus 9.5 msec in normal subjects and 81.6 plus or minus 18.9 msec in patients with congestive cardiomyopathy (p greater than 0.001). This time-interval correlates weakly with LVEDP (R = 0.04) and with ejection fraction (R = - 0.66). It is concluded that the normalized first derivative of QLAC provides useful information on left ventricular function.
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT