Determination of total blood volume by indicator dilution: a comparison of mean transit time and mass conservation
O Picker1, G Wietasch, T W Scheeren
1Department of Experimental Anaesthesiology, Heinrich-Heine-University, Moorenstrasse 5, 40225 Düsseldorf, Germany. olaf.picker@uni-duesseldorf.de
Objective:
Using indocyanine green (ICG), blood volume can be determined within minutes according to the mass conservation principle by back-extrapolation of the concentration/time curve to the time of injection (BVTinj) or by the transit time approach (BVMTT) as the product of cardiac output and mean transit time (MTT) of ICG through the circulation. To see which factor accounts for the difference between the two methods we measured cardiac output and MTT independently and compared the volumes with those obtained by dilution of Evans blue (BVEB).
Design:
Prospective animal study.
Settings:
University department of experimental anaesthesiology.
Animals:
Six anaesthetised, spontaneously breathing dogs with chronically implanted ultrasound flow probes around the pulmonary artery.
Measurements And Results:
BVMTT and BVTinj agreed closely (48 +/- 2 ml.kg-1 and 49 +/- 2 ml.kg-1), but underestimated blood volume by about 40% compared with BVEB (75 +/- 1 ml.kg-1). Transit times measured were 33 +/- 1 s and should be about 50 s as calculated from the quotient of BVEB and cardiac output.
Conclusions:
Both methods underestimate blood volume by about the same extent compared with BVEB, probably because slowly perfused compartments are not detected during the short measurement period of 4 min. In the case of the transit time approach, rather short transit times result and in the case of the mass conservation principle, back-extra-polation yields rather high plasma concentrations of ICG at the time of injection. Accordingly, the two methods seem to be equivalent for measuring blood volume rapidly, although the absolute volume is underestimated by about 40%.
Related Concept Videos
Noncompartmental Analysis: Mean Transit, Absorption and Dissolution Time
One of the key parameters is the mean transit time (MTT), which refers to the total duration required for drug molecules to transit through the body. MTT is determined by calculating the ratio of the area under the moment curve to the area...
Conservation of Mass in Finite Cotrol Volume
A system is defined as a collection of unchanging contents, and the conservation of mass states that a system's mass is constant.
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
Titrimetric Methods: Types and Commonly Used Strategies
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's overall...
Applications of Integration to Find Blood Flow