Elution parameters in constant-pressure, single-ramp temperature-programmed gas chromatography
Related Experiment Video
Updated: Aug 15, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
1Fast GC Consulting, Hockessin, DE 19707, USA. lmblumberg@worldnet.att.net
Abstract:
The dependence of the degree of interaction of a solute with the stationary phase at the time of its elution from the column in temperature-programmed GC is best described by interaction level of the solute. The latter represents the fraction of a solute residing in the stationary phase relative to the total amount of the solute. A simple approach to the evaluation of interaction levels of eluting solutes in a single-ramp temperature program is proposed. In a single-ramp temperature program having no preceding temperature plateau, all solutes that elute at temperatures that are about 60 degrees C higher than the initial temperature of the heating ramp elute with nearly the same interaction levels that can be found as exp(-r), where r is dimensionless heating rate. A specially designed temperature plateau preceding the ramp causes all solutes eluting during the entire time of the ramp to elute with nearly the same interaction levels equal to exp(-r). A transformation of the interaction level of a solute into its retention factor or mobility factor (a fraction of a solute in a mobile phase in relation to the total amount of the solute) and vice versa is also described.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:15Temperature-programmed Deoxygenation of Acetic Acid on Molybdenum Carbide Catalysts
Published on: February 7, 2017
Related Concept Videos
Clausius-Clapeyron Equation
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Elution Process