Defibrillation and the geometry of the heart: a novel measurement with implications for defibrillation mechanisms
R A Malkin1, S R Smith, B K Hoffmeister
1Joint Program in Biomedical Engineering, University of Memphis, University of Tennessee-Memphis, USA. ramalkin@memphis.edu
Abstract:
We present a novel measurement for studying defibrillation mechanisms: the time course of changes in the size of the left ventricular (LV) cavity within 500 ms following defibrillation. Mechanical changes can be linked to electrical mechanisms via an understanding of excitation-contraction coupling. Eight mongrel dogs were internally defibrillated 5-50 seconds (including backup shocks) after the onset of 20 ventricular fibrillation (VF) episodes per animal. Two dimensional, short axis, LV cavity, ultrasound images were recorded at 30 frames per second just prior to inducing VF, during defibrillation and following the shock. Each frame was individually analysed to yield the LV cavity area as a function of time. Defibrillation shocks were followed by a highly reproducible phenomenon: (1) a dramatic and rapid increase in LV area, (2) a more or less prominent LV area plateau and (3) a decrease in the LV area. The peak fractional area increase ranged from 1.65 to 4.64 times larger than the baseline (LV area just prior to defibrillation), averaging 2.18 +/- 0.686. Successful shocks took significantly longer (p < 0.01) to return to 1.3 times the baseline (407 +/- 209 ms) than unsuccessful shocks (296 +/- 130 ms). Extrapolating to electrical mechanisms, our novel measurement demonstrates that defibrillation causes immediate relaxation and therefore suggests a significant role for deexcitation in defibrillation.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias VI: Management of Dysrhythmias
Cardiopulmonary Resuscitation III: AED Use