Patient-ventilator interactions in new modes of patient-triggered ventilation
1Division of Neonatology, Georgetown University Medical Center, Washington, DC 20007, USA.
Abstract:
Recently, synchronized modes of conventional mechanical ventilation became available for neonatal ventilatory support, but there has been little information regarding details of patient-ventilator interactions during pressure support, volume support, or any other volume-targeted modes of synchronized ventilation in newborn infants. Our objective was to obtain comparative data on patient-ventilator interactions and stability of delivered tidal volume (V(T)) for the different modes of synchronized mechanical ventilation in stable ventilated newborn infants. We examined the effects of pressure support ventilation (PSV) and volume guarantee (VG) modes of a prototype Dräger Babylog ventilator on peak and mean airway pressures (PIP and Paw), inspiratory time (t(in)), and V(T) in 23 ventilated newborn infants. Twelve infants were studied while on assist/control (AC) and 11 on synchronized intermittent mandatory ventilation (SIMV). Mean birth weight was 1,650 +/- 1,180 g, gestational age 31 +/- 6 weeks, and age at time of study was 19 +/- 26 days. Data for 400-600 breaths from each infant were downloaded directly from the ventilator pressure and volume-monitoring module, and analyzed using ANOVA for repeated measures. Mean values and breath-to-breath variability were compared for 20-min periods of AC or SIMV followed by PSV, PSV+VG, and back to baseline AC or SIMV. PSV and PSV+VG led to shorter t(in) and thus to lower Paw, compared to AC. Mean PIP was similar across all AC modes but more variable during VG, reflecting the servocontrol of PIP. V(T) did not differ between AC modes, but was significantly less variable with VG added. PSV and PSV+VG led to lower and less variable PIP and Paw, compared to SIMV, because t(in) was shorter and every breath was supported in PSV and PSV+VG. V(T) was similar in SIMV, PSV, and PSV+VG, but less variable with PSV+VG. Arterial blood gas tensions were similar across all ventilation modes. We conclude that the ventilator prototype functioned as intended. Breath-to-breath tidal volume variability was significantly reduced in VG modes, although not completely eliminated.
More Related Videos
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
04:16Inspiratory Muscle Training as an Adjunct to the Treatment of Weaning Failure in Critically Ill Patients: A Practical Guide
Published on: January 30, 2026
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Cardiopulmonary Resuscitation II: ACLS Airway Management