Related Experiment Video
Updated: Oct 5, 2026

Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology
Published on: October 3, 2016
Autoclave performance and operator knowledge of autoclave use in primary care: a survey of UK practices
W A Coulter1, C A Chew-Graham, S W Cheung
1Department of Microbiology, School of Dentistry, Queen's University of Belfast, Grosvenor Road, Belfast BT12 6BP, Northern Ireland, UK. w.coulter@qub.ac.uk
Abstract:
Changes in the delivery of health care have increased the demand for minor surgical and screening procedures in general practice. This has increased the risk of cross-infection with blood-borne viruses and the demand for sterile instruments. The aim of this study was to investigate the knowledge and training of medical personnel in England and Wales on aspects of autoclave use, and to test the effectiveness of their practice autoclaves. An anonymous postal questionnaire and autoclave performance survey using biological indicators was made of 700 general medical practitioners selected at random from FHSA lists from 12 Health Authorities in England and Wales. The overall response rate was 53.1% (N= 372) comprising 10% general practitioners and 90% practice nurses. Eighty-two percent of respondents used autoclaves with a mean age of 2.5 years, of which 91% had been serviced in the past year. While 35% of respondents made daily observation of gauges, 19% did not routinely monitor autoclave effectiveness. Six autoclaves failed to sterilize the spore test ampoules. Fourteen percent of respondents did not autoclave instruments after every patient. Only 33.1% reported wearing gloves during minor operations. Fifty five percent had training in cross-infection prevention. It was concluded that although there has been improvement in instrument decontamination procedures in general practice compared with previous surveys, further education of medical practitioners and practice nurses in the use of autoclaves and infection prevention and control is indicated. The failure of 2% of the autoclaves to kill spores suggests the need for increased monitoring of autoclave performance. Two-thirds of practitioners exposed themselves to increased risk of infection by carrying out minor surgery without the protection of gloves.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Key Techniques in Microbiology
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...