Related Experiment Videos
Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery
J G Person1, A J Hodgson, A G Nagy
1Department of Mechanical Engineering, University of British Columbia, Vancouver, BC, Canada V6T 1Z4.
Background:
Despite widespread acknowledgement that strain injuries do occur to surgeons, ergonomic assessments in minimally invasive surgery are comparatively rare. Current assessment techniques rely on labor-intensive manual recording techniques, so there is a need for an automated system.
Methods:
We used an optoelectronic measurement system to make postural measurements at frequencies of ~5 Hz and then converted these measurements to ergonomic stress scores using a modified Rapid Upper Limb Assessment (RULA) method.
Results:
We successfully recorded postures at least once per second during 96% of the time the surgeon was performing tissue manipulation tasks. We found that the ergonomic stress scores were comparatively high throughout the procedure, particularly for the wrist.
Conclusion:
An automated high-frequency postural measurement system is feasible for making ergonomic assessments in an intraoperative setting. Such a system will also be a critical component in validating surgical simulations for use in training and credentialing surgeons and in designing and evaluating equipment.