Protocol for X-ray dosimetry in radiobiology
Related Experiment Video
Updated: Sep 20, 2026

Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
J Zoetelief1, J J Broerse, R W Davies
1Interfaculty Reactor Institute, Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands. j.zoetelief@iri.tudelft.nl
Purpose:
To harmonize X-ray dosimetry in radiobiology to allow a direct comparison of radiobiological studies performed at institutes cooperating within the framework of the European Late Effects Project Group (EULEP).
Materials And Methods:
The 1985 EULEP protocol for X-ray dosimetry and exposure arrangements employed for studies of late somatic effects in mammals required serious revision, e.g. due to the replacement of calibration of dosemeters in terms of exposure by calibration in terms of air kerma free-in-air. An action group established by EULEP and the European Radiation Dosimetry Group (EURADOS) updated the 1985 protocol.
Results:
The new EULEP-EURADOS protocol for X-ray dosimetry in radiobiology including the code of practice for irradiation of small animals and related dosimetry. The present protocol includes the changes in calibration procedures and dosimetric concepts for irradiation with medium energy X-rays since 1985. Accuracy and precision are replaced by the concept of combined (standard) uncertainty. The revised supplements provide more detailed background information. New appendices contain definitions of general terms used for measurements and mathematical expressions of the relative variances.
Conclusion:
Adherence to the present protocol will result in improved dosimetry and facilitates the comparison of results of radiobiological experiments obtained at different institutes.
Related Concept Videos
Biological Effects of Radiation
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
X-ray Imaging
Radiological Investigation I: X-ray and CT
Dosage Regimens: Partial Pharmacokinetic Parameters
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...