Related Experiment Video
Updated: Jul 28, 2026

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Heliox improves gas exchange during high-frequency ventilation in a pediatric model of acute lung injury
A Katz1, M A Gentile, D M Craig
1Department of Pediatrics, Duke University Medical Center, Durham, NC 27710, USA.
Abstract:
Because heliox has a lower density as compared with air, we postulated that heliox would improve gas exchange during high-frequency oscillatory ventilation (HFOV) in a model of acute lung injury. In a prospective, cross-over trial, we studied 11 piglets with acute lung injury created by saline lavage. With initial conditions of permissive hypercapnia (Pa(CO(2)) 55-80 mm Hg), each piglet underwent HFOV with a fixed mean airway pressure, pressure oscillation, and ventilatory frequency. The following gas mixtures were used: oxygen-enriched air (60% O(2)/40% N(2)) and heliox (60% O(2)/ 40% He and 40% O(2)/60% He). Compared with oxygen-enriched air, the 40% and 60% helium gas mixtures reduced Pa(CO(2)) by an average of 10.5 and 20.3 mm Hg, respectively. A modest improvement in oxygenation was seen with the 40% helium mixture. We conclude that heliox significantly improves carbon dioxide elimination and modestly improves oxygenation during HFOV in a model of acute lung injury. On the basis of test lung data and plethysmography measurements, we also conclude that heliox improves carbon dioxide elimination primarily through increased tidal volume delivery. Although heliox improved gas exchange during HFOV in our model, increased tidal volume delivery may limit clinical applicability.
Related Concept Videos
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-IV
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...