Assessment of Plasma Coagulation on Liver Tissue in a Large Animal Model In Vivo
Published on: August 4, 2018
Quantitative evaluation of hypothermia, hyperthermia, and hemodilution on coagulation
S A Kmiecik1, J L Liu, T S Vaadia
1Division of Clinical Perfusion Education, School of Allied Health Professions, University of Nebraska Medical Center, Omaha 68198-5155, USA. skmiecik@unmc.edu
Abstract:
The purpose of this study was to investigate the effects of temperature change on the coagulation time of blood at two different hematocrit levels by using various coagulation-monitoring devices. The devices used in this study were the Bayer Rapid Point Coag Analyzers, Hemochron Jr. Signature, Hemochron Response, Medtronic ACT II, and Haemoscope Thrombelastograph. One unit of human bank blood was used in this study. The hematocrit level was adjusted to 40% and 20%. A control bath and experimental bath were set up. Control blood was maintained at 37 degrees C and tested every 45 +/- 15 min throughout the experimental period of 6 h to demonstrate the stability of the model. The experimental blood was tested at temperature points of 37, 32, 27, 32, 37, 42, and 37 degrees C. Activated clotting time (ACT) tended to increase when the temperature was initially decreased from 37 to 27 degrees C, which reached a statistically significant level when measured by the Hemochron Response at both the 20% (147 +/- 10.7 to 159.3 +/- 11.0, p < .0332) and 40% hematocrit level (130 +/- 14.9 to 152.1 +/- 19.7, p < .0148). ACT was decreased significantly (p < .05) when the temperature was increased to 42 degrees C as measured by all machines except the Hemochron Jr. Signature at the 20% hematocrit level. ACT was significantly higher (p < .05) at a 20% hematocrit level as compared to that at a 40% hematocrit level on all devices for the majority of temperature points. These data suggested that hypothermia only increased ACT when measured by a macrosample device requiring a milliliter sample (Hemochron Response). However, hemodilution induced anticoagulatory effects and hyperthermia caused an acceleration in coagulation by all devices utilized in this study.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...