Rapid and portable methods of lactose tolerance test administration
The American Journal of Clinical Nutrition
|August 1, 1975
Summary
Portable methods for lactose tolerance testing are effective. The Ames Reflectance Meter/Dextrostix system accurately diagnoses lactose intolerance, even without a final blood sample.
Area of Science:
- Gastroenterology
- Clinical Chemistry
Background:
- Lactose intolerance diagnosis relies on accurate blood glucose monitoring during lactose tolerance tests.
- Standardized methods can be cumbersome, necessitating investigation into abbreviated, portable alternatives.
Purpose of the Study:
- To evaluate the efficacy of the Ames Reflectance Meter/Dextrostix system as a portable method for lactose tolerance testing.
- To compare its results against the standard AutoAnalyzer method.
- To assess the impact of omitting the final blood sample on test outcomes.
Main Methods:
- Lactose tolerance tests were administered to subjects.
- Blood glucose levels were measured using both the Ames Reflectance Meter/Dextrostix system and the AutoAnalyzer.
- Subjects with a maximum blood glucose rise below 20 mg/100 ml were classified as lactose nondigesters.
Main Results:
- The Ames Reflectance Meter/Dextrostix system demonstrated highly similar results to the AutoAnalyzer for determining maximum blood glucose rise and diagnosing lactose nondigesters.
- Maximum blood glucose elevations typically occurred before the final sample collection in both methods.
- Omitting the final blood sample did not alter the diagnostic outcome of the lactose tolerance test in any case.
Conclusions:
- The Ames Reflectance Meter/Dextrostix system provides a reliable and portable alternative for lactose tolerance testing.
- Abbreviated testing protocols, including the omission of the final blood sample, are valid for diagnosing lactose intolerance.