Related Experiment Video
Updated: Aug 9, 2026

MALDI Sample Preparation: the Ultra Thin Layer Method
Published on: April 29, 2007
Two-layer sample preparation method for MALDI mass spectrometric analysis of protein and peptide samples containing
1Department of Chemistry, University of Alberta, Edmonton, Canada.
Abstract:
Sodium dodecyl sulfate (SDS) is widely used in protein sample workup. However, many mass spectrometric methods cannot tolerate the presence of this strong surfactant in a protein sample. We present a practical and robust technique based on a two-layer matrix/sample deposition method for the analysis of protein and peptide samples containing SDS by matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). The two-layer method involves the deposition of a mixture of sample and matrix on top of a thin layer of matrix crystals. It was found that for SDS-containing samples, the intensity of the MALDI signals can be affected by the conditions of sample preparation: on-probe washing, choice of matrix, deposition method, solvent system, and protein-to-SDS ratio. However, we found that, under appropriate conditions, the two-layer method gave reliable MALDI signals for samples with levels of SDS up to approximately 1%. The applications of this method are demonstrated for MALDI analysis of hydrophobic membrane proteins as well as bacterial extracts. We envision that this two-layer method capable of handling impure samples including those containing SDS will play an important role in protein molecular weight analysis as well as in proteome identification by MALDI-MS and MS/MS.
More Related Videos
08:01LERLIC-MS/MS for In-depth Characterization and Quantification of Glutamine and Asparagine Deamidation in Shotgun Proteomics
Published on: April 9, 2017
08:16Optimal Preparation of Formalin Fixed Samples for Peptide Based Matrix Assisted Laser Desorption/Ionization Mass Spectrometry Imaging Workflows
Published on: January 16, 2018
Related Concept Videos
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...