Related Experiment Video
Updated: Aug 11, 2026

qPCRTag Analysis - A High Throughput, Real Time PCR Assay for Sc2.0 Genotyping
Published on: May 25, 2015
Increasing bioanalytical throughput using pcSFC-MS/MS: 10 minutes per 96-well plate
S H Hoke1, J A Tomlinson, R D Bolden
1Health Care Research Center, The Procter & Gamble Company, Mason, Ohio 45040, USA. hoke.sh@pg.com
Packed-column supercritical fluid chromatography (pcSFC) offers faster analysis times for high-throughput bioanalysis. This method, coupled with tandem mass spectrometry (MS/MS), enables rapid quantification of drugs in plasma samples.
Area of Science:
- Analytical Chemistry
- Chromatography
- Mass Spectrometry
Background:
- Packed-column supercritical fluid chromatography (pcSFC) is gaining traction for high-throughput analyses.
- Compared to traditional liquid chromatography, pcSFC uses volatile mobile phases (like CO2) reducing viscosity for faster flow rates.
- The volatile nature of pcSFC mobile phases is compatible with mass spectrometry (MS), allowing direct effluent analysis.
Purpose of the Study:
- To demonstrate the utility of pcSFC coupled with tandem mass spectrometry (pcSFC-MS/MS) for high-throughput bioanalytical quantitation.
- To validate pcSFC-MS/MS for pharmacokinetic applications using dextromethorphan as a model compound.
- To assess the speed, accuracy, and precision of the pcSFC-MS/MS method for analyzing plasma samples.
Main Methods:
- Plasma samples were processed using automated liquid/liquid extraction in a 96-well format.
- Dextromethorphan was analyzed using packed-column supercritical fluid chromatography coupled with tandem mass spectrometry (pcSFC-MS/MS).
- Method validation included three days of accuracy and precision assessments for quality control samples at various concentrations.
Main Results:
- Quantification of dextromethorphan in 96-well plates was achieved at a rate of approximately 10 minutes per plate.
- The method demonstrated excellent intraday accuracy, with results within 9% of the true value.
- Daily relative standard deviations (RSDs) for quality control samples were consistently below 10% (for higher concentrations) and below 15% (for lower concentrations).
Conclusions:
- pcSFC-MS/MS is a highly efficient technique for high-throughput bioanalytical quantitation in pharmacokinetic studies.
- The method provides rapid analysis with high accuracy and precision, suitable for processing large numbers of samples.
- This approach facilitates faster drug development by enabling quicker analysis of patient samples.
More Related Videos
12:02Automated Modular High Throughput Exopolysaccharide Screening Platform Coupled with Highly Sensitive Carbohydrate Fingerprint Analysis
Published on: April 11, 2016
09:24Automated Sample Multiplexing by using Combined Precursor Isotopic Labeling and Isobaric Tagging (cPILOT)
Published on: December 18, 2020