Electrocardiographic analysis of ectopic atrial activity obscured by ventricular repolarization: P wave isolation
A Sippensgroenewegen1, M D Mlynash, F X Roithinger
1Department of Medicine and the Cardiovascular Research Institute, University of California at San Francisco, 94143-1354, USA.
Introduction:
Atrial activity on the surface ECG during premature beats and supraventricular arrhythmias frequently is obscured by the superimposed QRST complex of the previous cardiac cycle. This study examines the performance of a newly developed automatic QRST subtraction algorithm to isolate ectopic P waves from the preceding T-U wave.
Methods And Results:
The 62-lead ECG recordings were obtained during (1) sinus rhythm and programmed right atrial stimulation in 12 patients (group A); and (2) sinus rhythm and atrial premature beats, atrial tachycardia, or paroxysmal atrial fibrillation in 5 patients (group B). Pacing in group A patients was conducted at a slow drive cycle length to generate an ectopic P wave not obscured by the previous QRST complex and by delivering single premature extrastimuli at progressively shorter coupling intervals to produce an ectopic P wave obscured by the upsloping (early T-U wave), peak (middle T-U wave), and downsloping component of the T-U wave (late T-U wave). All ectopic P waves in group B patients were concealed by the preceding T-U wave. Automatic QRST subtraction was attained using an adaptive template constructed from averaged QRST complexes (mean 83 +/- 25 complexes) obtained during sinus rhythm (groups A and B) or atrial overdrive pacing (group A). P wave integral maps subsequently were computed, visually compared, and mathematically correlated. A high correspondence in spatial map pattern was observed between integral maps of "nonobscured" and previously "obscured" paced P waves obtained in group A patients (mean r = 0.88 +/- 0.07) as well as between integral maps of two to three previously obscured P waves with the same atrial arrhythmia morphology obtained in group B patients (mean r = 0.94 +/- 0.05). Improved morphologic P wave replication in group A patients was acquired when concealment occurred in the early (mean r = 0.90 +/- 0.08) or late part of the T-U wave (mean r = 0.90 +/- 0.06) as opposed to the middle T-U wave (mean r = 0.85 +/- 0.07) (P = NS and P < 0.05 for early vs middle and late vs middle T-U wave, respectively).
Conclusion:
This novel automatic 62-lead QRST subtraction algorithm enables discrete isolation of T-U wave obscured ectopic atrial activity on the surface ECG while retaining the intricate spatial detail in P wave morphology. Future clinical application of the algorithm may enable improved ECG localization of focal triggers of paroxysmal atrial fibrillation, atrial tachycardia, and the atrial insertion of accessory pathways.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias