Related Experiment Video
Updated: Oct 5, 2026

Micro-drive Array for Chronic in vivo Recording: Tetrode Assembly
Published on: April 22, 2009
Editorial: Dedicated to the Memory of Marshall R. Urist
William Becker1, Lars Rasmusson, Karl-Erik Kahnberg
1Department of Oral and Maxillofacial Surgery, Department of Biomaterials/Handicap Research, Göteborg University, Göteborg, Sweden.
Abstract:
BACKGROUND: Previous experimental studies have shown a higher degree of bone-implant contact for surface-enlarged implants compared with machined implants. Yet, there is insufficient evidence that such implants show higher stability and an increased survival rate. PURPOSE: The purpose of this investigation was to study the integration and stability of grit-blasted implants with retention elements on the implant neck, with and without marginal bone defects, compared with machined implants without retention elements. MATERIALS AND METHODS: After tooth extraction of the mandibular premolars in six dogs, two grit-blasted, partly microthreaded Astra Tech implants and one standard Brånemark implant were bilaterally placed in each dog. On one side, 3 yen 3 mm large buccal defects were created, to expose three to four implant threads. The contralateral side served as control, and no defects were made. The animals were sacrificed after 4 months of healing. Implant stability was measured using resonance frequency analysis at implant installation and after 4 months of healing. Histologic and histomorphometric evaluation was made after 4 months of healing. RESULTS: Resonance frequency analysis indicated that all implants in the test and control groups were osseointegrated after 4 months, with a tendency toward higher implant stability for the Astra Tech implants. There was a statistically significant higher increase in resonance frequency for the Astra test implants compared with their corresponding controls. Histology and histomorphometry showed well-integrated implants with varying degrees of bone repair at the defect sites. The greater bone-implant contact for the Astra implants was statistically significant. No significant difference between the implants in amount of bone filling the threads was recorded. CONCLUSIONS: The Astra Tech implants tested showed a higher degree of bone-implant contact and higher level of bone regenerated at defect sites compared with the Brånemark implants. Resonance frequency analysis demonstrated a significantly higher increase in the Astra test implants compared with their control groups than did the Brånemark test implants versus their controls.
Related Concept Videos
Motor Units
Motor Units
Motor units come in different sizes, with smaller units...
Archival Research
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
System of Memory
RL Circuits
