A threshold ambiguity problem involving a cardiac pacemaker.

D J Lulu, J R Buysman

    The American Surgeon
    |July 1, 1975
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Electrocardiographic manifestations of the rapid recharge function of pulse generators after sensing.

    Pacing and clinical electrophysiology : PACE·1988
    Same author

    Delayed return of electrocardiographic tracing after defibrillatory electric shock caused by electrocardiographic monitor/electrode incompatibilities.

    The American journal of cardiology·1978
    Same author

    Truncal vagotomy and pyloroplasty. Critical evaluation of one hundred cases.

    American journal of surgery·1974
    Same author

    Primary total proctocolectomy for ulcerative colitis.

    The American surgeon·1974
    Same author

    Hypokalemia and pacemaker failure.

    The American surgeon·1974
    Same author

    Role of the gastric antrum in gastric hypersecretion after jejunal reversal.

    American journal of surgery·1974
    Same journal

    Complete Response of Merkel Cell Carcinoma to Immunotherapy and Single-Fraction Radiotherapy Following Severe COVID-19 Infection: A Case Report and Review of Immune Mechanism.

    The American surgeon·2026
    Same journal

    Perioperative Acute Myocardial Infarction in Non-Cardiac Operations: A National Analysis.

    The American surgeon·2026
    Same journal

    Outcomes of Completion Cholecystectomy: Association With Patient Comorbidity in a National Database.

    The American surgeon·2026
    Same journal

    Building the Conversation: Editorial Stewardship in Contemporary Surgical Publishing.

    The American surgeon·2026
    Same journal

    Musculoskeletal Pain in Surgeons on Operating Days.

    The American surgeon·2026
    Same journal

    Splenectomy During Cytoreductive Surgery: Marker of Surgical Burden or Independent Predictor of Morbidity?

    The American surgeon·2026
    See all related articles

    This case report highlights how external and internal pulse generator designs affect cardiac capture thresholds. Understanding these differences is key for accurate threshold determination in patients with pacemakers.

    Area of Science:

    • Cardiac Electrophysiology
    • Medical Device Engineering

    Background:

    • Cardiac pacing relies on delivering electrical stimuli to achieve myocardial capture.
    • The threshold for cardiac capture can be influenced by the characteristics of the pulse generator used.

    Purpose of the Study:

    • To present a case report illustrating a paradoxical electrical threshold for cardiac capture.
    • To explore how variations in the construction of external versus internal pulse generators impact this threshold.

    Main Methods:

    • Case report analysis focusing on electrical threshold measurements.
    • Discussion of the electrical characteristics inherent to external and internal pulse generator designs.

    Main Results:

    • Observed paradoxical electrical thresholds for cardiac capture were linked to differences in pulse generator construction.

    Related Experiment Videos

  • External and internal pulse generators exhibit distinct electrical properties affecting capture efficacy.
  • Conclusions:

    • Recommendations are provided for improving the reliability of cardiac capture threshold determinations.
    • Awareness of device-specific electrical characteristics is crucial for accurate pacing threshold assessment.