Maximal versus feigned active cervical motion in healthy patients: the coefficient of variation as an indicator for
Z Dvir1, T Prushansky, C Peretz
1Department of Physical Therapy, Sackler Faculty of Medicine, Tel Aviv University, Ramat Aviv, Israel. zdvir@post.tau.ac.il
Study Design:
Maximal and submaximal (feigned) cervical motions in healthy patients were compared.
Objective:
To test the efficiency of the coefficient of variation in differentiating maximal (sincere) from submaximal (feigned) cervical motion in healthy patients.
Summary Of Background Data:
Although limitation of cervical motion is a recognized impairment, no well-founded approach for verifying the degree to which a patient is maximizing his or her performance is available currently.
Methods:
A new ultrasound-based system for three-dimensional motion analysis of the head was used to test 25 healthy patients (22 women and 3 men) ages 26 to 48 years. During the first test, (Test 1), the patients were asked initially to move the head maximally at a self-determined velocity in all the primary directions: flexion, extension, right and left rotation, and right and left lateral flexion. They then were presented with a short vignette describing a fictitious accident and asked, using the same protocol, to perform the same types of cervical motions as if they had experienced an injury. No further instructions were provided. A retest (Test 2) in reverse order (feigned effort first) took place 1 to 16 weeks (mean, 3.3 weeks) later.
Results:
The range of motion and average velocity were significantly smaller (P = 0.0001) in the feigned than in the maximal performance in all directions and on both tests. Feigned range of motion and velocity also were significantly reduced in Test 2 (P = 0.006), as compared with those in Test 1 (P = 0.0001). The range of motion coefficient of variation in the feigned performance (CVf) remained stable on the retest, but was significantly larger on both tests (P < 0.001) than the corresponding CV derived from maximal performance (CVm). Furthermore, a case-by-case analysis showed that whereas the American Medical Association guidelines identified only 16% of the feigned cases, the use of CVf and CVm resulted in a corresponding rate of 87%. Tolerance intervals at 95% and 99% indicated total separation between the distributions of CVf and CVm, respectively. The average velocity-based CVf and CVm were not of a comparable differentiating power.
Conclusions:
This study indicates that in healthy patients, feigned performance may be differentiated from maximal (sincere) performance effectively and reproducibly using the coefficient of variation.
More Related Videos
Related Concept Videos
Coefficient of Variation
The coefficient of variation is a practical statistical tool in finance. It allows investors to assess the volatility or...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
McNemar's Test
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: