In this study we present a design for a multi-frequency microwave radiometer aimed at prolonged monitoring of deep brain temperature in newborn infants and suitable for use during hypothermic neural rescue therapy. We identify appropriate hardware to measure brightness temperature and evaluate the accuracy of the measurements. We describe a method to estimate the tissue temperature distribution from measured brightness temperatures which uses the results of numerical simulations of the tissue temperature as well as the propagation of the microwaves in a realistic detailed three-dimensional infant head model. The temperature retrieval method is then used to evaluate how the statistical fluctuations in the measured brightness temperatures limit the confidence interval for the estimated temperature: for an 18 degrees C temperature differential between cooled surface and deep brain we found a standard error in the estimated central brain temperature of 0.75 degrees C. Evaluation of the systematic errors arising from inaccuracies in model parameters showed that realistic deviations in tissue parameters have little impact compared to uncertainty in the thickness of the bolus between the receiving antenna and the infant's head or in the skull thickness. This highlights the need to pay particular attention to these latter parameters in future practical implementation of the technique.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...