Related Experiment Video
Updated: Aug 17, 2026

Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
UV Raman spectral intensities of E. coli and other bacteria excited at 228.9, 244.0, and 248.2 nm
1Chemistry Department, Princeton University, New Jersey 08544, USA.
Abstract:
Resonance Raman spectral intensities per average bacterial cell have been measured quantitatively for Gram-negative Escherichia coli, Citrobacter freundii, and Enterobacter aerogenes, as well as Gram-positive Bacillus subtilis and Staphylococcus epidermidis. Spectra have been obtained from cultures in the lag, log, and stationary growth phases excited in turn by 228.9, 244.0, and 248.2 nm light. Although Raman spectral peak positions (cm(-1)) excited by a given wavelength are very similar for all five bacterial species, the organisms are characterized by significantly different spectral intensity values. Intensity changes are associated with growth phase changes in all of the species as well. A comparison of measured with estimated average intensities has been made for spectra of log-phase E. coli. It is possible to compare measured intensities with intensities estimated for log-phase E. coli on the basis of the knowledge of its known average cellular molecular composition. A significant degree of hypochromism is observed in E. coli nucleic acid spectra. In contrast, strong average hyperchromism characterizes all aromatic amino acid peaks belonging to the same E. coli cells. Results suggest that knowledge of spectral intensity values will enhance significantly the capability to identify bacteria by means of their UV resonance Raman spectra.
Related Concept Videos
UV–Vis Spectroscopy: Beer–Lambert Law
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in the...
Molecular Spectroscopy: Absorption and Emission
UV–Vis Spectroscopy: Molecular Electronic Transitions
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...

