Related Experiment Video
Updated: Oct 5, 2026

In Vivo Telemetry to Record Long-Term Cardiovascular Parameters, Temperature, and Activity in Spinal Cord Injury Rat Models
Published on: January 2, 2026
Central and peripheral haemodynamics in individuals with paraplegia during light and heavy exercise
D Theisen1, Y Vanlandewijck, X Sturbois
1Department of Physical Education and Rehabilitation, Faculty of Medicine, Catholic University of Louvain, Louvain-la-Neuve, Belgium.
Abstract:
The purpose of this study was to analyse lower leg skin blood flow (laser Doppler flowmetry) in five individuals with high-level paraplegia (T5-T9), six participants with low-level paraplegia (T10-T12) and six able-bodied controls during 3-minute light and heavy arm-cranking exercises (approximately 15% and 80% peak power output, respectively). Throughout light exercise, cutaneous vasoconstriction was shown for the control group (-20%), but not the low-level (+62%) or the high-level paraplegic group (+33%). During heavy exercise, vasoconstriction was initially found for controls followed by an increase in skin blood flow during the last 2 minutes, whereas the participants with paraplegia demonstrated skin blood flow increases. Skin blood flow responses were not related to lesion level. Metabolic parameters were not different among the three groups, but heart rates for participants with paraplegia were higher during heavy exercise than in controls. These results suggest impaired sympathetic vasoconstriction in individuals with paraplegia during exercise.
More Related Videos
07:32Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals
Published on: June 8, 2017
09:18Doppler Ultrasound-Based Leg Blood Flow Assessment During Single-Leg Knee-Extensor Exercise in an Uncontrolled Setting
Published on: December 15, 2023
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Artery Disease V: Postoperative Nursing Management
Peripheral Artery Disease IV: Nursing Management
Assessing Blood pressure in the Leg
Preparation:
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...