Apical extrusion of debris and irrigants using two hand and three engine-driven instrumentation techniques
Related Experiment Video
Updated: Oct 5, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
C C Ferraz1, N V Gomes, B P Gomes
1Department of Restorative Dentistry, Piracicaba School of Dentistry, University of Campinas, Brazil. cferraz@fop.unicamp.br
Aim:
To evaluate the weight of debris and irrigant volume extruded apically from extracted teeth in vitro after endodontic instrumentation using the balanced force technique, a hybrid hand instrumentation technique, and three engine-driven techniques utilizing nickel-titanium instruments (ProFile .04, Quantec 2000 and Pow-R).
Methodology:
Five groups of 20 extracted human teeth with single canals were instrumented using one or other of five techniques: balanced force, hybrid, Quantec 2000, ProFile .04, or Pow-R. Debris extruded from the apical foramen during instrumentation were collected into preweighed 1.5 mL tubes. Following instrumentation, the volume of extruded irrigant fluid was determined by visual comparison to control centrifuge tubes filled with 0.25 mL increments of distilled water. The weight of dry extruded dentine debris was also established.
Results:
Overall, the engine-driven techniques extruded less debris than the manual ones. However, there was no statistical difference between the balanced force technique and the engine-driven methods. The volume of irrigant extruded through the apex was directly associated with the weight of extruded debris, except within the ProFile group. The hybrid technique was associated with the greatest extrusion of both debris and irrigant.
Conclusions:
Overall, the engine-driven nickel-titanium systems were associated with less apical extrusion.
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning II: Procedure
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...