Purpose:
The increased demand for tooth-colored restorations has prompted the use of ceramics in areas that are subject to masticatory stresses. To maximize the strength of these restorations, manufacturers and clinicians advocate placement of core materials in lieu of veneering materials in areas that are more susceptible to fracture. The objectives of this study were to determine the: resistance to staining of three core porcelains used for all-ceramic restorations, Procera, IPS Empress, and In-Ceram, through the use of colorimetry and visual observation; flexural strength of these porcelains under a three-point bend test; and chemical solubility in a controlled environment.
Materials And Methods:
L*a*b* values were obtained for each specimen before and after immersion in a saturated solution of methylene blue in ethanol for 24 hours. Visual observation was also performed to ascertain color differences before and after staining. A three-point bend test was used to determine flexural strength. A reflux-condenser type, three-piece extraction apparatus was used with 4% acetic acid solution for 16 hours to determine solubility. Each sample was weighed before and after the reflux procedure to ascertain percentage weight loss.
Results:
The mean delta E obtained for IPS Empress was 14.5; In-Ceram was 9.2, and Procera was 9.0. Flexural strength obtained for IPS Empress, In-Ceram, and Procera was 176.9 MPa, 323.4 MPa, and 464.3 MPa, respectively. Weight loss of IPS Empress, In-Ceram, and Procera was 0.056%, 0.734%, and 0.003%, respectively.
Conclusion:
IPS Empress showed the least resistance to staining. IPS Empress had the lowest flexural strength, while Procera had the highest. In-Ceram demonstrated the highest chemical solubility.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:37Evaluating the Effects of Different Polishing Methods on Color Stability of Dental Restorations in Pediatric Dentistry
Published on: June 6, 2025
Related Concept Videos
Physical Properties Affecting Solubility
As for any solution, the solubility of a gas in a liquid is affected by the attractive intermolecular forces between solute and solvent species. Unlike solid and liquid solutes, however, there is no solute-solute intermolecular attraction to overcome when a gaseous solute dissolves in a liquid solvent since the atoms or molecules comprising a gas are far separated and experience negligible interactions. Consequently, solute-solvent interactions are the sole...
Factors Affecting Solubility
Mortar Properties
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the aggregate...
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...