Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Published on: February 14, 2017
Evaluation of cardiovascular parameters of a selenium-based antihypertensive using pulsed Doppler ultrasound
J D Overcast1, A E Ensley, C J Buccafusco
1School of Chemistry and Biochemistry and School of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.
Abstract:
The pharmacology of selenium is of much interest because selenium deficiency has been linked to cardiovascular diseases, cancer, and arthritis, and selenoenzymes are critical cellular antioxidants. We have previously reported that phenyl-2-aminoethylselenide (PAESe) and its derivatives represent a novel class of selenium-based antihypertensive agents that exhibit unique biochemical and pharmacologic properties. We now report on experiments designed to probe the hemodynamic mechanism of action of these compounds in spontaneously hypertensive rats (SHR). A noninvasive pulsed Doppler ultrasound probe was used to measure peak blood flow velocity in the aortic arch from the right second intercostal space. PAESe was found to increase peak aortic blood flow velocity (+44%), heart rate (+16%), and blood flow acceleration (+105%), while decreasing left ventricular ejection time (LVET) (-37%) concomitant with a decrease in mean arterial pressure (-54%). These results were compared with the known vasodilator hydralazine, which had similar effects on mean arterial pressure (MAP) and peak velocity but caused an increase in LVET (+42%) and a decrease in heart rate (-18%). Taken together, our results suggest that PAESe decreases blood pressure via a decrease in peripheral resistance, which overcomes the initial increase in heart rate and acceleration to give a net decrease in MAP.
Related Concept Videos
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...