In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
An in vitro study of the effects of isoflurane on oxygen transfer
M L Muhle1, A H Stammers, K D Tremain
1Division of Clinical Perfusion Education, School of Allied Health Professions, University of Nebraska Medical Center, Omaha 68198-5155, USA. mmuhle@home.com
Abstract:
A common anesthetic technique utilized during cardiopulmonary bypass (CPB) includes the use of various inhalation agents, such as isoflurane. The purpose of this study was to evaluate the effects of this agent on oxygen transfer during CPB. An in vitro model was designed using bovine blood. Blood flow was held constant at 2 l/min, while gas flow was manipulated at 1 and 3 l/min. The percentage of inspired oxygen (FiO2) was set at 50 and 100%, and isoflurane was manipulated to 1.0, 3.0 and 5.0%. Blood gas analysis, oxygen transfer, and inlet and outlet isoflurane concentrations were measured at each of the given conditions. A total of 12 trials with four oxygenators were conducted. In the four oxygenators used in our study, no significant differences in oxygenator performance were found. At conditions of 1 I/min gas flow, 50% FiO2 and 1% isoflurane, there were no significant changes in O2 transfer between baseline and measurements taken during isoflurane administration (100.18 +/- 12.49 vs 102.35 +/- 10.99 ml O2/min, p=0.8031). At 3 I/min gas flow, 100% FiO2 and 5% isoflurane, no significant differences were found (142.35 +/- 10.76 vs 154.04 +/- 8.95 ml O2/min, p=0.1459). The only significant differences found for oxygen transfer were between 50 and 100% FiO2, all other conditions being set equal (102.35 +/- 10.99 vs 137.68 +/- 8.62 ml O2/min, p=0.0023). In conclusion, increasing concentrations of isoflurane up to 5% does not affect the efficiency of oxygen transfer in an in vitro circuit. Further studies are necessary to evaluate the effects in an in vivo setting.
More Related Videos
08:16Optogenetic Activation of Afferent Pathways in Brain Slices and Modulation of Responses by Volatile Anesthetics
Published on: July 23, 2020
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Transport in the Blood
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...