A variable critical-volume model for normal tissue complication probability.

D V Bonta1, E Fontenla, Y Lu

  • 1Department of Radiation and Cellular Oncology, University of Chicago, Illinois 60637, USA. d-bonta@uchicago.edu

Medical Physics
|August 8, 2001
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Determination of methanol and acetaldehyde in the air of workplace by solvent desorption-headspace gas chromatography].

Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases·2026
Same author

Development of a high-speed small-angle infrared thermography system in EAST.

The Review of scientific instruments·2023
Same author

[Study on the correlation between ceramic and chronic obstructive pulmonary disease in Foshan City].

Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases·2023
Same author

Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program.

Journal of applied clinical medical physics·2003
Same author

Using serial imaging data to model variabilities in organ position and shape during radiotherapy.

Physics in medicine and biology·2001
Same author

Numerical analysis of a model of organ motion using serial imaging measurements from prostate radiotherapy.

Physics in medicine and biology·2001
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

This study introduces a novel normal-tissue complication probability (NTCP) model for radiotherapy, focusing on high-dose regions and critical organ volumes. The model accurately predicts late-term rectal complications, improving conformal radiotherapy optimization.

Area of Science:

  • Radiation Oncology
  • Medical Physics
  • Biostatistics

Background:

  • Accurate prediction of normal-tissue complication probability (NTCP) is crucial for optimizing conformal radiotherapy.
  • Existing models may not fully capture the complexities of dose-volume relationships in normal tissue damage.

Purpose of the Study:

  • To develop and validate a new NTCP model based on high-dose region properties.
  • To identify the critical volume within an organ that most influences complication probability.

Main Methods:

  • Proposed a novel NTCP model incorporating dose-volume effects and a critical volume concept.
  • Utilized a power law to scale dose-volume relationships to a whole-organ equivalent dose.
  • Employed a logistic distribution and maximum likelihood estimation for model parameter fitting.

Related Experiment Videos

Main Results:

  • The new model demonstrated good correspondence between predictions and experimental data for late-term rectal complications.
  • Identified a critical volume within the rectum that is most sensitive to radiation dose.
  • The model effectively predicts normal-tissue complication probability based on dose to the critical volume.

Conclusions:

  • The proposed NTCP model offers a promising approach for predicting late-term normal-tissue complications.
  • This model can aid in optimizing radiotherapy planning, particularly for prostate cancer patients.
  • Understanding critical volume effects is essential for improving radiotherapy safety and efficacy.