Quantitation of volatile oils in ground cumin by supercritical fluid extraction and gas chromatography with flame
D L Heikes1, B Scott, N A Gorzovalitis
1Williams Foods, Inc, Lenexa, KS 66215-1348, USA.
Abstract:
Ground cumin is used as a flavoring agent in a number of ethnic cuisines. The chemical entities, which primarily establish its characteristically pungent flavor, are found in the volatile oil of cumin. Fixed oils and carbohydrates tend to round out the harshness of the volatile oil components. However, the quantity of volatile oil is commonly the measure of the quality of this spice. For several decades, the spice industry has used a classical distillation procedure for the determination of volatile oil in cumin and other spices. However, the method is cumbersome and requires nearly 8 h to complete. Supercritical fluid extraction with capillary gas chromatography-flame ionization detection is utilized in the formulation of a rapid, accurate, and specific method for the determination of volatile oil in ground cumin. Samples are extracted in a static-dynamic mode with CO2 at 550 bar and 100 degrees C. Toluene is used as a static modifier addition. The extracted volatile oil, collected in toluene, is analyzed directly using tetradecane as the internal standard. Integration is performed as grouped peaks to include all chemical entities found in cumin volatile oil recovered from the official distillation procedure. Results from this procedure compare favorably with those obtained by the official procedure (coefficient of correlation = 0.995, 24 samples).
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Volatilization
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...