Related Experiment Video
Updated: Oct 5, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Stacking and separation of coproporphyrin isomers by acetonitrile-salt mixtures in micellar electrokinetic
1Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, PR China.
Abstract:
The effectiveness of the addition of salt and acetonitrile in the sample matrix to induce narrowing of the analyte zones is demonstrated for the first time in micellar electrokinetic chromatography (MEKC). Using coproporphyrin (CP) I and III isomers as test compounds, the use of sodium cholate (SC) as the micelle in the separation buffer and a high concentration of sodium chloride in the aqueous sample solution (without the presence of an organic solvent) were found to provide enhancement in peak heights for both CP I and III, but yielded very poor resolution of these two positional isomers at sample size of 10% capillary volume or larger. With the addition of acetonitrile as the organic solvent in the aqueous sample solution (acetonitrile-salt mixtures), baseline/partial resolution of CP I and III was obtained even at large injection volumes, along with significant increase in peak heights for both isomers. Possible mechanisms responsible for the narrowing of analyte zones are briefly discussed. The effects of experimental parameters, such as concentrations of salt and acetonitrile, on peak heights and resolution of the test compounds were studied. Importantly, the usefulness of the present method was demonstrated for the MEKC determination of endogenous CP I and III present in normal urine samples with good separation and detection performances.
More Related Videos
07:51A Multi-Omics Extraction Method for the In-Depth Analysis of Synchronized Cultures of the Green Alga Chlamydomonas reinhardtii
Published on: August 8, 2019
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Related Concept Videos
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Extraction: Advanced Methods
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...