Comparative analysis of DNA content estimated by flow and image cytometry in breast tumor samples
A Jaszcz-Gruchała1, I Swiatkiewicz, B Lackowska
1Department of Tumor Pathology, Oncology Center, Kraków.
Abstract:
The DNA ploidy status of 186 fresh primary breast tumors was analyzed in a comparative study of flow cytometric (FCM) and image (IA) analyses. Tumor size, histology and nodal status were also taken into account. The same piece of fresh tissue was used for touch imprints (IA) and for DNA analysis by FCM. Both methods provided concordant DI values in 158 (85%) tumors (r = 0.7490). The tumor grade and lymph node status significantly correlate with ploidy estimated by FCM and IA. We conclude that FCM and IA provide comparable results of DNA content although occasional discrepancies occur. IA seems to be a more sensitive method especially for diploid cases detected by FCM.