Strategies for determination of insulin with tandem electrospray mass spectrometry: implications for other analyte
C Fierens1, D Stöckl, L M Thienpont
1Laboratorium voor Analytische Chemie, Universiteit Gent, Harelbekestraat 72, 9000 Gent, Belgium.
Abstract:
Using human insulin (MW 5808 Da) as a model compound, the possible strategies towards optimization of sensitivity and selectivity of measurement by electrospray ionization with a standard triple quadrupole mass spectrometer were investigated. For measurement in selected ion-monitoring (SIM) mode, these strategies involved systematic variation of instrumental parameters and spray pH. In this investigation four different operating modes were used corresponding to positive/negative ionization modes with acidic/basic sprays and pH reversed (hereafter termed 'wrong-way-round' operation); the cone voltage was optimized for each mode of operation. When collision-activated dissociation (CAD) is employed, two additional operation modes are possible: namely, low collision energies (10-35 eV, CAD-l) for the generation of sequence-specific fragments and high collision energies (>80 eV, CAD-h) for the generation of nonspecific fragments. Overall, this results in twelve different modes of operation. Loop-injection of aqueous insulin standards were run for each of the twelve operating modes and measurements made for five different charge states (n = 2-6) observable with our instrument that has an upper mass limit of m/z 4000. The signal/noise (S/N) ratio was optimized for each charge state, resulting in 60 measurements. The best S/N ratios (20 000) were achieved under positive SIM conditions with charge state 6 (m/z 969) and under 'wrong-way-round' negative SIM conditions with charge state 3 (m/z 1935). Lower S/N ratios were observed under positive CAD-h conditions with charge state 5 (m/z 1163, S/N 15 000) and positive CAD-l conditions with charge state 6 (m/z 969, S/N 10 000). All other operating modes gave maximum S/N ratios of 4000. For measurement of insulin standards, the results obtained show SIM to give the best S/N ratio. However, for samples in complex matrices, our general experience suggests CAD to be the preferable operating mode. Consequently, for the development of a quantitative method for proteins in general, it might be advocated that all of the twelve operating modes and all relevant charge states be investigated to find the optimum S/N ratio.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
MALDI-TOF Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)