Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
A new double cuff sphygmotonometer for accurate blood pressure measurement
O Tochikubo1, J Watanabe, K Hanada
1Department of Public Health, Yokohama City University School of Medicine, Japan.
Abstract:
Accurate measurement of blood pressure (BP) is essential in the diagnosis and treatment of hypertension, but neither auscultatory nor oscillometric methods measure intra-arterial BP accurately in all circumstances. Algorithms for automatic BP-measuring devices differ from manufacturer to manufacturer, and no clear authorized algorithm criteria have yet been established. We have devised a double-cuff sphygmotonometer to measure BP on the basis of clear algorithms, and investigated the accuracy of this new method by comparing it with the photo-oscillometric method, which is the most accurate method for non-invasive measurement of intra-arterial BP. In the new method, a small cuff (3x6 cm) replaces the photo-sensor in the brachial cuff (13x24 cm) of the photo-oscillometric device, and BP is determined by means of the oscillation within the small cuff. The comparison based on procedures of AAMI-protocol was performed in 136 hypertensive patients and 54 normotensive subjects. The difference in systolic BP between the photooscillometric and double-cuff methods was -2.26+/-2.31 mmHg (89% under 5 mmHg), and the corresponding difference in diastolic BP was 1.9+/-2.50 mmHg (94% under 5 mmHg). In conclusion, we have devised a new double-cuff method which improves on the photo-oscillometric method, and although it seems to be less accurate than the photo-oscillometric method, the clarity of its algorithm makes it superior to the conventional oscillometric and auscultatory methods employing only one cuff.
More Related Videos
05:51Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure