X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Comparison of algorithms for combining X-ray angiography images
K S Kump1, G M Saidel, D L Wilson
1Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.
Abstract:
Using a one-dimensional convective-dispersive model of contrast agent flow in a blood vessel, we optimized and compared algorithms for combining a temporal sequence of X-ray angiography images, each with incomplete arterial filling, into a single-output image with fully opacified arteries. The four algorithms were: maximum opacity (MO) with a maximum over time at each spatial location; matched filtering (MAT); recursive filtering (REC) with a maximum opacity; and an approximate matched filter (AMF) consisting of a correlation with a kernel that approximates the matched filter kernel followed by a maximum opacity operation. Based on the contrast-to-noise ratio (CNR), MAT is theoretically the best algorithm. However, with spatially varying clinical images, a poorly matched MAT kernel greatly degraded CNR to the point of even inverting artery contrast. The practical AMF method maintained uniform CNR values over the entire field of view and gave >90% of the theoretical limit set by MAT. REC and MO created fully opacified arteries, but provided little CNR enhancement. By holding CNR at a nominal reference value, simulations predicted that AMF could be used with a contrast agent volume reduced by as much as 66%. Alternatively, X-ray exposure rate could be lowered. Although MO and REC are more easily implemented, the contrast enhancement with AMF makes it attractive for processing diagnostic angiography images acquired with a reduced contrast agent dose.
More Related Videos
05:26Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies VII: Vascular Imaging