Related Experiment Video
Updated: Aug 18, 2026

Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Enantiomer separation by nonaqueous and aqueous capillary electrochromatography on cyclodextrin stationary phases
D Wistuba1, K Cabrera, V Schurig
1Institute for Organic Chemistry, University of Tübingen, Germany. dorothee.wistuba@uni-tuebingen.de
Abstract:
Native beta- and gamma-cyclodextrin bound to silica (ChiraDex-beta and ChiraDex-gamma) were packed into capillaries and used for enantiomer separation by capillary electrochromatography (CEC) under aqueous and nonaqueous conditions. Negatively charged analytes (dansyl-amino acids) were resolved into their enantiomers by nonaqueous CEC (NA-CEC). The addition of a small amount of water to the nonaqueous mobile phase enhanced the enantioselectivity but increased the elution time. The choice of the background electrolyte (BGE) determined the direction of the electroosmotic flow (EOF). With 2-(N-morpholino) ethanesulfonic acid (MES) or triethylammonium acetate (TEAA) as BGE an inverse EOF (anodic EOF) was observed while with phosphate a cathodic EOF was found. The apparent pH (pH*), the concentration of the BGE, and the nature of the mobile phase strongly influenced the elution time, the theoretical plate number and the chiral separation factor of racemic analytes.
More Related Videos
10:41Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Related Concept Videos
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...