Related Experiment Video
Updated: Sep 20, 2026

Extraction and Analysis of Microbial Phospholipid Fatty Acids in Soils
Published on: August 26, 2016
Liquid-liquid-liquid microextraction of nitrophenols with a hollow fiber membrane prior to capillary liquid
Abstract:
A simple liquid-liquid-liquid microextraction device utilizing a 2 cm x 0.6 mm I.D. hollow fiber membrane was used to preconcentrate nitrophenols from water sample prior to capillary liquid chromatography (cLC) analysis. The extraction procedure was induced by the pH difference inside and outside the hollow fiber. The donor phase outside the hollow fiber was adjusted to pH approximately 1 with HCl; the acceptor phase was NaOH solution used at various concentrations. Organic solvent was immobilized into the pores of the hollow fiber. With stirring, the neutral nitrophenols outside the fiber were extracted into the organic solvent, then back extracted into 2 microl of basic acceptor solution inside the fiber. The acceptor phase was then withdrawn into a microsyringe and injected into the cLC system directly. This technique used a low-cost disposable extraction "device" and is very convenient to operate. Up to 380-fold enrichment of analytes could be achieved. This procedure could also serve as a sample clean-up step because large molecules and basic compounds were not extracted into the acceptor phase. The RSD (n=6) was less than 6.2%, while the linear calibration range was from 1 to 200 microg/ml with r>0.998. The procedure was applied to the analysis of seawater.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...