Atmospheric volatile organic compound measurements during the 1996 Paso del Norte Ozone Study

R L Seila1, H H Main, J L Arriaga

  • 1US Environmental Protection Agency, National Exposure Research Laboratory, Research Triangle Park, NC 27711, USA. Seila.Robert@epa.gov

Related Concept Videos

Vapor Pressure02:34

Vapor Pressure

When a liquid vaporizes in a closed container, gas molecules cannot escape. As these gas phase molecules move randomly about, they will occasionally collide with the surface of the condensed phase, and in some cases, these collisions will result in the molecules re-entering the condensed phase. The change from the gas phase to the liquid is called condensation. When the rate of condensation becomes equal to the rate of vaporization, neither the amount of the liquid nor the amount of the vapor...
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Pulmonary Function Tests01:25

Pulmonary Function Tests

Pulmonary Function Tests (PFTs)
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Drug Concentrations: Measurements01:23

Drug Concentrations: Measurements

Drug concentration is the quantity of a drug present in a biological sample. Measuring drug amounts in biological samples allows the clinician to understand how a drug is absorbed, distributed, metabolized, and excreted. Samples can be obtained through invasive or non-invasive methods. Invasive techniques involve surgical or parenteral interventions to gather blood, cerebrospinal fluid, or tissue biopsy. Conversely, non-invasive approaches provide samples like urine, feces, and saliva.
Plasma —...