Waveform optimization for internal atrial defibrillation: effects of waveform rounding, phase duration, and voltage
B J Kidwai1, J D Allen, M T Harbinson
1Regional Medical Cardiology Center, Royal Victoria Hospital, Belfast, Ireland.
Abstract:
The aim of this study was to compare the efficacy of internal atrial defibrillation by conventional truncated exponential biphasic waveforms with and without waveform rounding (1-2 phases) and to determine optimal duration for this novel double rounded waveform. Atrial fibrillation, induced by rapid electrical stimulation, was converted by internal shocks through defibrillation catheters (lateral right atrium and coronary sinus) in anesthetised sheep. Rounding the leading edges of the conventional biphasic waveform (Ventritex HVS-02; settings 100/-50 V, 150/-70 V, and 200/-100 V; n = 8) reduced delivered peak and trough voltages, currents, and energy (by > or = 21 %, P < 0.001; for double (both phases) rounded) without decreasing cardioversion success. At 100/-50 V the efficacy of single (first phase) rounded (53 +/- 13%; mean +/- SEM) and double rounded (59 +/- 11%) shocks was similar to the conventional waveform (56 +/- 14%). Double rounded waveform (phase durations 1-20 ms) efficacy was optimum at 6-10 ms phase duration (100% success at 10-ms phase duration; 1.52 +/- 0.04 J delivered energy; n = 6). Successful cardioversion by conventional, single rounded, and double rounded biphasic waveforms (duration 6 ms each phase), conventional monophasic, rounded monophasic (duration 12 ms), and a damped sine waveform correlated strongly with peak-to-trough voltage swing within the waveform (r = 0.882; P < 0.01; n = 8). For internal atrial defibrillation, rounding both phases of the conventional biphasic waveforms, the double rounded waveform, permits similar efficacy to the conventional truncated exponential biphasic waveform at reduced peak voltage, current, and delivered energy. Optimum phase duration is 6-10 ms (tested range 1-20 ms).
Related Concept Videos
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias VI: Management of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias