A Pacing-Controlled Procedure for the Assessment of Heart Rate-Dependent Diastolic Functions in Murine Heart Failure Models
Published on: July 21, 2023
Ambulatory blood pressure in heart failure
1Department of Pharmacology, University of Texas Health Science Center San Antonio, 78249-6205, USA. jamieson@uthscsa.edu
Abstract:
Ambulatory blood-pressure monitoring (ABPM) is accepted in the evaluation and management of hypertension. The use of ABPM in heart failure has received considerably less attention. Many patients with advanced heart failure experience disabling fatigue, orthostatic dizziness and symptoms of coronary and cerebrovascular insufficiency that may relate to periods of hypotension. These may be exacerbated by vasodilator drug therapy and may be difficult to evaluate by casual clinic recordings. ABPM in heart failure may help in the following: (i) evaluating time-dependent pharmacodynamic drug effects, such as peak and end-of-dose phenomena, tolerance and rebound; (ii) titrating ACE inhibitors and other drugs to highest-tolerated doses; and (iii) correlating circadian blood-pressure profiles with symptoms, quality of life, severity of heart failure, progression of ventricular and renal dysfunction, risks of stroke and myocardial infarction, and life expectancy. Devices for ABPM have been beset by problems of inaccuracy and unreliability. Standards for their manufacture and sale (including bench tests of accuracy against sphygmomanometry and intra-arterial recordings, and field tests of reliability) have been devised independently by several agencies, including the British Hypertension Society (BHS) and US Association for the Advancement of Medical Instrumentation (AAMI). A joint BHS/AAMI set of guidelines is in preparation. These guidelines emphasize the suitability of ABPM devices for hypertensive patients and those under general anesthesia, and may not be applicable to ambulant individuals with heart failure and blood pressures at or below the lower end of the evaluated ranges. Prospective studies of the accuracy and reliability of ABPM devices, their clinical utility and research potential should be undertaken in patients with heart failure before their informal and uncontrolled use in this population becomes widespread.
More Related Videos
04:05Clinical Application of Phase Angle and BIVA Z-Score Analyses in Patients Admitted to an Emergency Department with Acute Heart Failure
Published on: June 30, 2023
05:16Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pathophysiology of Heart Failure
Heart Failure II: Pathophysiology
Heart Failure V: Medical Management
Heart Failure VI: Adjunct Therapies
Heart Failure VII: Nursing Interventions