Related Experiment Video
Updated: Aug 15, 2026

Longitudinal Evaluation of Mouse Hind Limb Bone Loss After Spinal Cord Injury using Novel, in vivo, Methodology
Published on: December 7, 2011
Bone loss from the hand in women following distal forearm fracture
Bone loss occurs after distal forearm fracture, but it is unclear if this bone loss is fully recovered. We designed a cross-sectional study to evaluate the time course of the bone loss from the hand after distal forearm fracture. We identified 40 women who had a fracture of the distal forearm within the previous 4.5 years. Their ages ranged from 42 to 81 (mean 64 years) and time since fracture 6 to 54 (mean 28 months). These were compared with 95 women (mean age 67, range 57 to 80 years) from a population-based cohort. Lumbar spine (LS) and hand bone mineral density (BMD) were measured in all subjects using a Hologic QDR 1000/W densitometer. Ultrasound of the fingers of both hands was measured in the forearm fracture group using a DBM Sonic 1200 R model. Compared to controls, LS BMD was decreased by 6.4% (p<0.001), non-fractured hand by 3.2% (p<0.001) and the fractured hand by 6.1% (p<0.001) in the forearm fracture group. The mean difference in bone density between the fractured and non-fractured hand was 0.0207 g/cm2, the average value for the non-fractured hand being 0.304 g/cm2. The decement in hand BMD was equivalent to 6.2% (p<0.0001). The difference in hand BMD between the fractured and non-fractured side was greatest when the time since fracture was short; there was no further difference in hand BMD after 2 years. Ultrasound showed a mean difference of 18.7 m/s in amplitude-dependent speed of sound (AD-SoS) with the average value being 1893 m/s. A 1.0% decrease was observed in the fractured hand AD-SoS (p<0.05). A strong relationship was observed between AD-SoS and BMD in both hands (r = 0.70, p<0.001). We conclude that distal forearm fracture results in a significant decrease in hand BMD that is partially reversible. The decrease in hand BMD is reflected in the ultrasound properties of the finger phalanx.
Bone loss occurs after distal forearm fracture, but it is unclear if this bone loss is fully recovered. We designed a cross-sectional study to evaluate the time course of the bone loss from the hand after distal forearm fracture. We identified 40 women who had a fracture of the distal forearm within the previous 4.5 years. Their ages ranged from 42 to 81 (mean 64 years) and time since fracture 6 to 54 (mean 28 months). These were compared with 95 women (mean age 67, range 57 to 80 years) from a population-based cohort. Lumbar spine (LS) and hand bone mineral density (BMD) were measured in all subjects using a Hologic QDR 1000/W densitometer. Ultrasound of the fingers of both hands was measured in the forearm fracture group using a DBM Sonic 1200 R model. Compared to controls, LS BMD was decreased by 6.4% (p<0.001), non-fractured hand by 3.2% (p<0.001) and the fractured hand by 6.1% (p<0.001) in the forearm fracture group. The mean difference in bone density between the fractured and non-fractured hand was 0.0207 g/cm2, the average value for the non-fractured hand being 0.304 g/cm2. The decement in hand BMD was equivalent to 6.2% (p<0.0001). The difference in hand BMD between the fractured and non-fractured side was greatest when the time since fracture was short; there was no further difference in hand BMD after 2 years. Ultrasound showed a mean difference of 18.7 m/s in amplitude-dependent speed of sound (AD-SoS) with the average value being 1893 m/s. A 1.0% decrease was observed in the fractured hand AD-SoS (p<0.05). A strong relationship was observed between AD-SoS and BMD in both hands (r = 0.70, p<0.001). We conclude that distal forearm fracture results in a significant decrease in hand BMD that is partially reversible. The decrease in hand BMD is reflected in the ultrasound properties of the finger phalanx.
Related Concept Videos
Bone Remodeling
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
Bones of the Upper Limb: Humerus
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...

