Related Experiment Video
Updated: Aug 12, 2026

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Contrast echocardiography improves the accuracy and reproducibility of left ventricular remodeling measurements: a
H L Thomson1, A J Basmadjian, A J Rainbird
1Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA.
Objectives:
We sought to assess the impact of contrast injection and harmonic imaging, on the measure by echocardiography of left ventricular (LV) remodeling.
Background:
Left ventricular remodeling is a precursor of LV dysfunction, but the impact of contrast injection and harmonic imaging on the accuracy or reproducibility of echocardiography is unclear.
Methods:
We prospectively collected LV images by using simultaneous methods. Then, LV volumes were measured off-line, in blinded manner and in random order. The accuracy of echocardiography was determined in comparison to electron beam computed tomography (EBCT) in 26 patients. The reproducibility of echocardiography was assessed by three blinded observers with different training levels in 32 patients.
Results:
End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF), as measured by EBCT (195 +/- 55, 58 +/- 24 and 137 +/- 35 ml and 71 +/- 5%, respectively) and echocardiography with harmonic imaging and contrast injection (194 +/- 51, 55 +/- 20 and 140 +/- 35 ml and 72 +/- 4%, respectively), showed no differences (all p > 0.15) and excellent correlations (all r > 0.87). In contrast, echocardiography using harmonic imaging without contrast injection underestimated the EBCT results (all p < 0.01). Reproducibility was superior with rather than without contrast injection for intraobserver and interobserver variabilities (all p < 0.001). Values measured by different observers were different without contrast injection, but were similar with contrast injection (all p > 0.18). Consequently, intrinsic patient differences represented a larger and almost exclusive proportion of global variability with contrast injection for EDV (94 vs. 79%), ESV (93 vs. 82%), SV (87 vs. 53%) and EF (84 vs. 41%), as compared with harmonic imaging without contrast injection (all p < 0.005).
Conclusions:
For assessment of LV remodeling, echocardiography with harmonic imaging and contrast injection improved the accuracy and reproducibility, as compared with imaging without contrast injection. With contrast injection, variability was almost exclusively due to intrinsic patient differences. Therefore, when evaluation of LV remodeling is deemed important, assessment after contrast injection should be the preferred echocardiographic approach.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...

