Related Experiment Video
Updated: Aug 16, 2026

Procedure for Human Saphenous Veins Ex Vivo Perfusion and External Reinforcement
Published on: October 1, 2014
Preserved endothelial integrity and nitric oxide synthase in saphenous vein grafts harvested by a 'no-touch'
J C Tsui1, D S Souza, D Filbey
1Department of Surgery, Royal Free and University College Medical School, London, UK.
Insights
The novel "no-touch" saphenous vein harvesting technique preserves endothelial integrity and nitric oxide synthase (NOS) better than conventional methods. This may improve coronary artery bypass graft patency and reduce graft occlusion.
Area of Science:
- Cardiovascular Surgery
- Vascular Biology
- Surgical Techniques
Background:
- Saphenous veins are primary grafts for coronary artery bypass surgery.
- Conventional harvesting causes significant vein damage, leading to high graft occlusion rates (up to 30% at 1 year).
- Endothelial integrity and nitric oxide synthase (NOS) are critical for graft patency.
Purpose of the Study:
- To compare endothelial integrity and NOS in saphenous veins harvested using a novel "no-touch" technique versus conventional methods.
- To evaluate the impact of harvesting technique on key factors influencing graft patency.
Main Methods:
- Immunohistochemistry was used to assess endothelial integrity.
- Histochemistry and autoradiography identified nitric oxide synthase (NOS) distribution.
- Human saphenous veins harvested by both conventional and "no-touch" techniques were analyzed.
Main Results:
- No-touch grafts exhibited significantly better endothelial lining preservation (73%) compared to conventional grafts (52%; P=0.04).
- Reduced NOS availability was observed in conventional grafts.
- No-touch grafts retained NOS in the adventitial vasa vasorum, which are often removed during conventional harvesting.
Conclusions:
- Conventional saphenous vein harvesting removes sites crucial for nitric oxide release in vivo.
- "No-touch" harvesting preserves these sites, offering potential for improved coronary artery bypass graft patency.
- The findings suggest the "no-touch" technique may reduce graft occlusion rates.
Background:
The saphenous vein is the most commonly used conduit for coronary artery bypass surgery, but 1-year occlusion rates as high as 30 per cent have been reported. In conventional surgery, considerable damage to the vein occurs during harvesting. The aim of this study was to compare endothelial integrity and nitric oxide synthase (NOS) in saphenous veins harvested by a novel 'no-touch' technique and veins harvested conventionally.
Methods:
Immunohistochemistry was used to study endothelial integrity, and a combination of histochemistry and autoradiography was employed to identify NOS in human saphenous veins harvested by conventional and no-touch techniques.
Results:
The endothelial lining of conventional grafts was reduced compared with that of no-touch grafts (52 versus 73 per cent; P = 0.04). This was associated with a concomitant reduction of NOS availability; NOS was also present in the adventitial vasa vasorum of no-touch vessels.
Conclusion:
Some of the sites with potential for nitric oxide release in vivo are removed during conventional saphenous vein harvesting. These sites were preserved after no-touch harvesting, suggesting the potential to improve coronary artery bypass graft patency.
More Related Videos
09:04Synergizing Antegrade Endoscopic with Bridging Vein Harvesting for Improvement of Great Saphenous Vein Graft Quality from the Lower Leg
Published on: November 19, 2019
09:10Human Saphenous Vein Endothelial Cell Isolation and Exposure to Controlled Levels of Shear Stress and Stretch
Published on: April 21, 2023