Experimental parameters affecting hypercoulometric response in gas-phase coulometry.

P Ciccioli1, J M Hayes

  • 1Department of Chemistry, Indiana University, Bloomington 47405, USA.

Analytical Chemistry
|January 1, 1985
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Magnetization transfer ratio: a quantitative imaging biomarker for 5q spinal muscular atrophy.

European journal of neurology·2020
Same author

Toll-like receptors and inflammation in metabolic neuropathy; a role in early versus late disease?

Experimental neurology·2019
Same author

Nitrogen isotopic analyses by isotope-ratio-monitoring gas chromatography / mass spectrometry.

Journal of the American Society for Mass Spectrometry·2013
Same author

Polar volatile organic compounds (VOC) of natural origin as precursors of ozone.

Environmental monitoring and assessment·2013
Same author

Neurodegeneration and early lethality in superoxide dismutase 2-deficient mice: a comprehensive analysis of the central and peripheral nervous systems.

Neuroscience·2012
Same author

Long-range migration of intrinsic defects during irradiation or implantation.

Journal of physics. Condensed matter : an Institute of Physics journal·2011
Same journal

Heterojunction Gate-Empowered OPECT Aptasensing: A Valid Protocol for Realizing High Current Gain at Low Electron Donor Dependency.

Analytical chemistry·2026
Same journal

Development of a Tapping-Mode Scanning Probe Electrospray Ionization Platform for High-Sensitivity and Long-Term Stability in Single-Cell Mass Spectrometry Imaging of Tissue.

Analytical chemistry·2026
Same journal

A Solid-State Near-Infrared Fluorescent Probe by a Synergistic Extended Conjugated System for Detecting Cys with Long-Term Imaging in Orthotopic Bladder Cancer.

Analytical chemistry·2026
Same journal

Air-Based Porous Array Dielectric Barrier Discharge Ionization Source for Explosive Trace Detection.

Analytical chemistry·2026
Same journal

PSAQ<sup>+1</sup>: Absolute Protein Quantification Using a <sup>13</sup>C<sub>1</sub>-Labeled Protein Standard, Coisolation of Peptide Pairs and LC-PRM.

Analytical chemistry·2026
Same journal

Heterojunction-Enhanced Interfacial Evanescent-Tunable Fiber Optic Probe for Amplification-free CRISPR/Cas12a-Based Rapid and Ultrasensitive Detection of MPXV.

Analytical chemistry·2026
See all related articles

Achieving true coulometric response with electron-capture detectors is challenging. Detector response varies with operating conditions, making consistent 1:1 electron absorption difficult to maintain for accurate quantification.

Area of Science:

  • Analytical Chemistry
  • Chromatography
  • Environmental Science

Background:

  • Electron-capture detectors (ECDs) are widely used for trace analysis.
  • Coulometric response in ECDs aims for a 1:1 electron capture per molecule.
  • Maintaining stable coulometric operation is crucial for accurate quantification.

Purpose of the Study:

  • To investigate the factors affecting the coulometric response of an electron-capture detector.
  • To determine the conditions under which a 1:1 electron capture per molecule is achieved.
  • To identify deviations from ideal coulometric behavior and their causes.

Main Methods:

  • Examined ECD response as a function of solute, pulse interval, carrier gas, solute amount, flow rate, and peak profile.
  • Utilized chlorofluorocarbon (CCl3F) as a model solute.

Related Experiment Videos

  • Compared experimental results with theoretical expectations for electron capture.
  • Main Results:

    • The average electrons absorbed per molecule for CCl3F varied from 1.0 to 4.1.
    • Response variation was primarily dependent on pulse interval and sample amount.
    • Observed deviations from the expected 1:1 coulometric response under specific conditions.

    Conclusions:

    • True 1:1 coulometric response in ECDs is not always achieved due to complex dependencies on operating variables.
    • Maintaining stable coulometric operation requires careful control of multiple parameters, including sample amount.
    • Factors contributing to hypercoulometric response warrant critical consideration for accurate ECD analysis.