Inclusive inelastic scattering of heavy ions in the independent particle model

F A Cucinotta1, L W Townsend, J W Wilson

  • 1NASA, Langley Research Center, Hampton, VA 23665-5225.

Journal of Physics. G, Nuclear and Particle Physics : an Institute of Physics Journal
|May 1, 1992
PubMed

Related Concept Videos

Atomic Radii and Effective Nuclear Charge03:08

Atomic Radii and Effective Nuclear Charge

The elements in groups of the periodic table exhibit similar chemical behavior. This similarity occurs because the members of a group have the same number and distribution of electrons in their valence shells.
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Equilibrium Conditions for a Particle01:23

Equilibrium Conditions for a Particle

When an object is in equilibrium, it is either at rest or moving with a constant velocity. There are two types of equilibrium: static and dynamic. Static equilibrium occurs when an object is at rest, while dynamic equilibrium occurs when an object is moving with a constant velocity. In both cases, there must be a balance of forces acting on the object.
To understand the concept of equilibrium, let us first consider the forces acting on an object. When different forces act on an object, they can...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Principle of Linear Impulse and Momentum for a System of Particles01:21

Principle of Linear Impulse and Momentum for a System of Particles

In the context of a system of particles moving relative to an inertial frame of reference, the equation of motion is a crucial tool for understanding the dynamics of the system. This equation, which accounts for external forces acting on each particle, plays a fundamental role in describing the system's behavior.
Notably, internal forces between particles, occurring in equal and opposite collinear pairs, cancel out and are not part of the equation of motion. This exclusion simplifies the...