High-Resolution Respirometry in a Small-Volume Chamber
Published on: July 25, 2025
Oxygen levels in closed circuit UBAs during descent
1Department of Naval Architecture, Ocean and Marine Engineering, U.S. Naval Academy, Annapolis, MD 21402, USA.
Abstract:
Closed circuit rebreathers used by divers recirculate the respiratory gases through a scrubber to remove exhaled carbon dioxide. For systems used in deep diving applications, oxygen is mixed with a diluent gas to maintain a preset partial pressure of oxygen (PO2) that is within the physiologically acceptable limits for the diver. These systems accurately maintain the oxygen set point while the diver swims at constant depth. However, as a diver increases depth, the gas volume in his lungs and his underwater breathing apparatus (UBA) will be compressed. To avoid damage, a diluent gas, a breathable mixture of oxygen and some inert component such as nitrogen or helium, must be supplied to the breathing circuit to maintain constant volume. Because the composition of this diluent will normally be different from the desired circuit breathing mixture, it is important that the addition of this diluent will not have harmful physiological effects on the diver. The effects of UBA circuit volume, diver descent rate, oxygen consumption rate, and diluent composition on the oxygen partial pressures within the breathing circuit during descent are investigated in this article. Exposures to oxygen partial pressures in excess of 2.0 atmospheres absolute (ata) are shown to be possible during dives when using closed circuit UBAs with present PO2 levels of 0.7 ata. These elevated oxygen exposures are shown to diminish when a diver reaches depth, but could last in excess of 18 min during a dive to 200 ft of seawater.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Transport in the Blood
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...