Jet eccentricity: a misleading source of agreement between Doppler/catheter pressure gradients in aortic stenosis
M D VanAuker1, M Chandra, J Shirani
1Department of Medicine, State University of New York Health Science Center at Brooklyn, New York, USA. vanauker@eng.usf.edu
Abstract:
Characterization of the severity of aortic stenosis relies on accurate measurement of the pressure gradient across the valve and the valve area. Pressure gradients measured by Doppler ultrasound based on the clinical form of the Bernoulli equation often overestimate pressure gradients by catheter as the result of pressure recovery. Doppler techniques measure the velocity of the vena contracta of the stenotic jet. This corresponds to the maximal pressure gradient and the minimal effective valve area. Pressure recovery can be characterized by analysis of the spread of the stenotic jet downstream of the valve as it fills the aorta and should be influenced by the shape of the velocity profile of the decaying jet. In this study, we addressed the hypothesis that the site of complete pressure recovery (the point at which the jet fully expands to the size of the aorta), the effective valve area, and the maximal pressure gradient are affected by jet eccentricity. To accomplish this, we developed a computational model of aortic stenosis that provides detailed velocity and pressure information in the vicinity of the valve. The results show that the width of the eccentric wall jet decreased and maximal velocity increased with greater jet eccentricity. Furthermore, for a constant anatomic area, the effective valve area decreased, the distance to complete pressure recovery increased, and the maximal pressure gradient increased with the degree of eccentricity. Failure to take this into account could fortuitously drive Doppler and catheter measurements toward agreement because the distal pressure sensor will not record the fully recovered pressure. Therefore the pressure gradient across a stenotic valve depends on jet eccentricity. The spread of the wall jet after attachment must be characterized to develop a robust method for the prediction of pressure recovery.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Measurement of Blood Pressure
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests